5. Disconnect the White common (neutral) conductor from the dryer outlet (Figure 3) or disconnect
the White wire in hardwired installations (Figure 4) and extend this conductor with a length of wire
that is identical to the gauge and temperature rating of the White conductor.
6. This extended White wire will be run into the Current Switch 4” x 4” box and through the hole in
the Current Switch and then return to the terminal on the dryer outlet (Figure 3) or the White wire
going to the clothes dryer. (Figure 4).
The electricity going through this White conductor looped through the Current Switch makes the
Current Switch turn ON when the dryer is operating.
7. Check the wiring and connections and re-install the electrical dryer outlet and cover plate.
120 VAC Fan Connections:
8. Run 3 new wires (minimum 14 Gauge, 105ºC), Black (line or hot), White (common or neutral)
and Green (ground) 120 VAC to the service panel with a new breaker, or pick up the Black, White
and Green wires from a nearby 120 VAC outlet.
The new Black conductor connects to terminal T1 on the Current Switch.
9. Run a new Black conductor from the DRY04/DRY06 to terminal L1 on the Current Switch. The
new White and Green wires connect directly to the terminal block of the DRY04/DRY06.
10. All new wiring must be rated 14 Gauge minimum, 105ºC. and installed in rigid ½” conduit or
metal flexible conduit terminated at electrical boxes with the correct conduit connectors.
11. Install the cover plate on the box containing the Current Switch.